Smelting Industry

RAMON Hydrogen Measurement Instrument

basic information
heat:
没有此类产品
Description

Technical Index

1、Output Function 

Signal output: 4-20mA, Ethernet
Output display: RM-302 large screen display (50m visual range)
Sound alarm output: finish measurement

2、Measuring time

30-120s 

3、Measuring range

[H]: 0.5-14 ppm 

4、Output function

[H]< 2~ 0.50 ppm : ± 0.10 ppm

[H]≧2 ~ 14.0 ppm : ± 0.2 ppm

5、Data storage

100,000 times of measuring results 

6、Operation requirements 

Power supply: 220 VAC     50/60 Hz
Power: RM-300 online molten steel hydrogen measuring instrument  60W
RM-301 pneumatic control box 120W
Working condition: 0 ℃ to 50 ℃, relative humidity≤75%
Storage condition: -20 ℃ to 50 ℃, relative humidity≤75%
Nitrogen requirement: purity quotient≥99.99%,pressure≥0.5Mpa
 
Technology Advantages
Integrated TCD sensor is influenced less by environmental factors. Repeatable error< 1 PPM.
Developed based on X86 platform, the system is equipped with various signal interfaces to realize the connection with the steel plant secondary network without adding other network devices. 
Over 100,000 times of measurement data can be stored for more than 10 years, providing reliable basis for process improvement (The data storage of similar products is 110 times).
RAMON remote assistant software can be embedded to ensure timely and reliable service (Optional).
 
Benefit Analysis
The real-time online measurement of hydrogen content of molten steel can avoid expensive isothermal heat treatment, save energy,and increase productivity and benefits. 
It can judge the quality of the molten steel to guarantee casting billet desired internal tissue and prevent sticking-type breakout. 
Reduce the internal and external defects of the casting product. 
On a
RAMON Hydrogen Probe