Smelting Industry

RAMON Temperature & Oxygen Measuring Probe

basic information
heat:
没有此类产品
Description

Product function

This system provides effective data support to improve molten steel quality, ensure product qualification rate, increase finished product ration, and reduce material consumption.

Oxygen Probing Index

 

Type 

Accurate measuring 
range 

Oxygen potential 
deviation

Successful 
rate

Application

Medium and high oxygen probe     

10~1500 ppm

±5mV

98%

 Converter, EAF, Refining furnace

Low Oxygen(Aluminum Measuring) Probe 

1~1500 ppm

±5mV

95%

 LF, RH refining furnace

 
 

Temperature Measuring Technical Index

 

Thermocouple model 

 Measuring range       

 Standard Deviation  

B / R / S

1450°C ~1750°C

< 3 °C

 

Typical Measuring Curve:

Technical Advantage

High measuring precision, good stability and fast response speed.
The measurement of acid solube aluminium(ASA) or carbon content can be confirmed by active oxygen measurement
Oxygen battery and instruments are fully independent developed

Typical Cases:

He Steel, Nanjing Iron and Steel, Steel plant in Vietnam, Steel plant in Russia, Valin Iron and Steel, Steel plant in Taiwan, Steel plant in Middle East, etc. 

 

Steel Plant

Working Position

Oxygen Content(ppm)

 

http://1808010025.pool201-site.yun300.cn/repository/image/LExdtjsETFuc0eJjL8VtbQ.jpg

Steel plant in Vietnam  

At the back of Converter 

30~200

 

http://1808010025.pool201-site.yun300.cn/repository/image/q7zk883NQg6t0cM4QJiqjg.jpg

Valin Steel    

Converter and LF position 

Converter:200~700
Refining Furnace: 2~4.5

 

http://1808010025.pool201-site.yun300.cn/repository/image/mZUVAyp_T1io0QH5RRDIYA.jpg

Steel plant of Hebei Iron and Steel 

At the back of Converter         

30~200

 

http://1808010025.pool201-site.yun300.cn/repository/image/5xlNoR_nS1qmEZF3L6rDbw.jpg

Steel plant of Hebei  Iron and Steel    

      Converter         

200~700

 

 

 

 
On a
The next article
RAMON Sublance Probe